  the information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. this documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. it is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. neither schneider electric industries sas nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. 5 ? 2012 1 product data sheet characteristics ATV212HU22N4 variable speed drive atv212 - 2.2kw - 3hp - 480v - 3ph - emc - ip21 main range of product altivar 212 product or component type variable speed drive device short name atv212 product destination asynchronous motors product specific application pumps and fans in hvac assembly style with heat sink network number of phases 3 phases motor power kw 2.2 kw motor power hp 3 hp power supply voltage 380...480 v (- 15...10 %) power supply voltage limits 323...528 v supply frequency 50...60 hz (- 5...5 %) network frequency 47.5...63 hz emc filter class c2 emc filter integrated line current 3.6 a for 480 v 4.6 a for 380 v complementary apparent power 3.9 kva for 380 v prospective line isc 5 ka continuous output current 5.1 a at 380/460 v maximum transient current 5.6 a for 60 s speed drive output frequency 0.5...200 hz nominal switching frequency 12 khz switching frequency 6...16 khz adjustable 12...16 khz with derating factor speed range 1...10 speed accuracy +/- 10 % of nominal slip for 0.2 tn to tn torque variation torque accuracy +/- 15 % transient overtorque 120 % of nominal motor torque for 60 s asynchronous motor control profile voltage/frequency ratio, 2 points voltage/frequency ratio, 5 points flux vector control without sensor, standard voltage/frequency ratio - energy saving, quadratic u/f voltage/frequency ratio, automatic ir compensation (u/f + automatic uo) regulation loop adjustable pi regulator motor slip compensation adjustable automatic whatever the load not available in voltage/frequency ratio motor control local signalling 1 led - red - dc bus energized output voltage <= power supply voltage isolation electrical between power and control type of cable for external connection iec cable without mounting kit: 1 wire(s) - 45 c, copper 90 c / xlpe/epr iec cable without mounting kit: 1 wire(s) - 45 c, copper 70 c / pvc ul 508 cable with ul type 1 kit: 3 wire(s) - 40 c, copper 75 c / pvc electrical connection terminal 2.5 mm2 / awg 14 (via, vib, fm, fla, flb, flc, ry, rc, f, r, res) terminal 6 mm2 / awg 10 (l1/r, l2/s, l3/t)
2 tightening torque 0.6 n.m (via, vib, fm, fla, flb, flc, ry, rc, f, r, res) 1.3 n.m - 11.5 lb.in (l1/r, l2/s, l3/t) supply internal supply for reference potentiometer (1 to 10 kohm): 10.5 v dc, +/- 5 % - <= 10 a with overload and short-circuit protection internal supply: 24 v (21...27 v) dc - <= 200 a with overload and short-circuit protection analogue input number 2 analogue input type configurable ptc probe: (vib) 0...6 probes - 1500 ohm switch-configurable voltage: (via) 0...10 v dc - 24 v max - 30000 ohm - resolution: 10 bits switch-configurable current: (via) 0...20 ma - 250 ohm - resolution: 10 bits configurable voltage: (vib) 0...10 v dc - 24 v max - 30000 ohm - resolution: 10 bits sampling duration 2 ms +/- 0.5 ms (f) - discrete input(s) 2 ms +/- 0.5 ms (r) - discrete input(s) 2 ms +/- 0.5 ms (res) - discrete input(s) 3.5 ms +/- 0.5 ms (via) - analog input(s) 22 ms +/- 0.5 ms (vib) - analog input(s) response time 2 ms +/- 0.5 ms (fm) - analog output(s) 7 ms +/- 0.5 ms (fla, flc) - discrete output(s) 7 ms +/- 0.5 ms (flb, flc) - discrete output(s) 7 ms +/- 0.5 ms (ry, rc) - discrete output(s) accuracy +/- 0.6 % (via) for a temperature variation 60 c +/- 0.6 % (vib) for a temperature variation 60 c +/- 1 % (fm) for a temperature variation 60 c linearity error +/- 0.15 % of maximum value for input (via) +/- 0.15 % of maximum value for input (vib) +/- 0.2 % for output (fm) analogue output number 1 analogue output type switch-configurable voltage: (fm) 0...10 v dc - 7620 ohm - resolution: 10 bits switch-configurable current: (fm) 0...20 ma - 970 ohm - resolution: 10 bits discrete output number 2 discrete output type configurable relay logic: (fla, flc) no - 100000 cycles configurable relay logic: (flb, flc) nc - 100000 cycles configurable relay logic: (ry, rc) no - 100000 cycles minimum switching current 3 ma at 24 v dc (configurable relay logic) maximum switching current 5 a at 250 v ac on resistive load - cos phi = 1 - l/r = 0 ms (fl, r) 5 a at 30 v dc on resistive load - cos phi = 1 - l/r = 0 ms (fl, r) 2 a at 250 v ac on inductive load - cos phi = 0.4 - l/r = 7 ms (fl, r) 2 a at 30 v dc on inductive load - cos phi = 0.4 - l/r = 7 ms (fl, r) discrete input type programmable (f) 24 v dc, with level 1 plc - 4700 ohm programmable (r) 24 v dc, with level 1 plc - 4700 ohm programmable (res) 24 v dc, with level 1 plc - 4700 ohm discrete input logic positive logic (source) (f, r, res), <= 5 v (state 0), >= 11 v (state 1) negative logic (sink) (f, r, res), >= 16 v (state 0), <= 10 v (state 1) acceleration and deceleration ramps automatic based on the load linear adjustable separately from 0.01 to 3200 s braking to standstill by dc injection protection type overheating protection for drive thermal power stage for drive short-circuit between motor phases for drive input phase breaks for drive overcurrent between output phases and earth for drive overvoltages on the dc bus for drive break on the control circuit for drive against exceeding limit speed for drive line supply overvoltage and undervoltage for drive line supply undervoltage for drive against input phase loss for drive thermal protection for motor motor phase break for motor with ptc probes for motor dielectric strength 3535 v dc between earth and power terminals 5092 v dc between control and power terminals insulation resistance >= 1 mohm at 500 v dc for 1 minute frequency resolution 0.1 hz for display unit 0.024/50 hz for analog input
3 communication port protocol apogee fln bacnet lonworks metasys n2 modbus connector type 1 rj45 1 open style physical interface 2-wire rs 485 transmission frame rtu transmission rate 9600 bps or 19200 bps data format 8 bits, 1 stop, odd even or no configurable parity type of polarization no impedance number of addresses 1...247 communication service monitoring inhibitable read device identification (43) read holding registers (03) 2 words maximum time out setting from 0.1 to 100 s write multiple registers (16) 2 words maximum write single register (06) option card communication card for lonworks operating position vertical +/- 10 degree width 107 mm height 143 mm depth 150 mm product weight 2 kg power dissipation in w 103 w fan flow rate 35 m3/h environment electromagnetic compatibility electrostatic discharge immunity test level 3 conforming to iec 61000-4-2 radiated radio-frequency electromagnetic field immunity test level 3 conforming to iec 61000-4-3 electrical fast transient/burst immunity test level 4 conforming to iec 61000-4-4 1.2/50 s - 8/20 s surge immunity test level 3 conforming to iec 61000-4-5 conducted radio-frequency immunity test level 3 conforming to iec 61000-4-6 voltage dips and interruptions immunity test conforming to iec 61000-4-11 pollution degree 3 iec 61800-5-1 ip degree of protection ip21 conforming to en/iec 61800-5-1 ip21 conforming to en/iec 60529 ip41 on upper part conforming to en/iec 61800-5-1 ip41 on upper part conforming to en/iec 60529 ip20 on upper part without blanking plate on cover conforming to en/iec 61800-5-1 ip20 on upper part without blanking plate on cover conforming to en/iec 60529 vibration resistance 1.5 mm (f = 3...13 hz) conforming to en/iec 60068-2-6 1 gn (f = 13...200 hz) conforming to en/iec 60068-2-8 shock resistance 15 gn for 11 ms conforming to iec 60068-2-27 environmental characteristic classes 3c1 conforming to iec 60721-3-3 classes 3s2 conforming to iec 60721-3-3 noise level 51 db conforming to 86/188/eec relative humidity 5...95 % without condensation conforming to iec 60068-2-3 5...95 % without dripping water conforming to iec 60068-2-3 operating altitude <= 1000 m without derating 1000...3000 m (limited to 2000 m for the corner grounded distribution network) with current derating 1 % per 100 m ambient air temperature for operation -10...40 c without derating > 40...50 c with derating factor ambient air temperature for storage -25...70 c
4 standards en 55011 class a group 1 en 61800-3 en 61800-3 category c2 en 61800-3 category c3 en 61800-3 environments 1 category c1 en 61800-3 environments 1 category c2 en 61800-3 environments 1 category c3 en 61800-3 environments 2 category c1 en 61800-3 environments 2 category c2 en 61800-3 environments 2 category c3 en 61800-5-1 iec 61800-3 iec 61800-3 category c2 iec 61800-3 category c3 iec 61800-3 environments 1 category c1 iec 61800-3 environments 1 category c2 iec 61800-3 environments 1 category c3 iec 61800-3 environments 2 category c1 iec 61800-3 environments 2 category c2 iec 61800-3 environments 2 category c3 iec 61800-5-1 ul type 1 product certifications csa c-tick nom 117 ul marking ce
5 product data sheet dimensions drawings ATV212HU22N4 dimensions dimensions in mm atv212h a b g h j k ? 075m3x...u22m3x 075n4...u22n4 107 143 93 121.5 5 16.5 2 ? x ? ?5 u30m3x, u40m3x u30n4...u55n4 142 184 126 157 6.5 20.5 4 ? x ? ?5 dimensions in in. atv212h a b g h j k ? 075m3x...u22m3x 075n4...u22n4 4.21 5.63 3.66 4.78 0.20 0.65 2 ? x ? ?0.20 u30m3x, u40m3x u30n4...u55n4 5.59 7.24 4.96 6.18 0.26 0.81 4 ? x ? ?0.20 plate for emc mounting (supplied with the drive) (1) 2 x m5 screws dimensions in mm atv212h b1 c 075m3x...u22m3x 075n4...u22n4 49 67.3 u30m3x, u40m3x u30n4...u55n4 48 88.8 dimensions in in. atv212h b1 c 075m3x...u22m3x 075n4...u22n4 1.93 2.65 u30m3x, u40m3x u30n4...u55n4 1.89 3.50
6 product data sheet mounting and clearance ATV212HU22N4 mounting recommendations clearance depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate accessories. install the unit vertically: do not place it close to heating elements. leave sufficient free space to ensure that the air required for cooling purposes can circulate from bottom to the top of the unit. mounting types type a mounting type b mounting type c mounting by removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes ip21. the protective blanking cover may vary according to the drive model, see opposite. specific recommendations for mounting in an enclosure to help ensure proper air circulation in the drive: fit ventilation grilles. check that there is sufficient ventilation. if there is not, install a forced ventilation unit with a filter. the openings and/or fans must provide a flow rate at least equal to that of the drive fans (refer to the product characteristics). use special filters with ul type 12/ip54 protection. remove the blanking cover from the top of the drive.
7 sealed metal enclosure (ip54 degree of protection) the drive must be mounted in a dust and damp proof enclosure in certain environmental conditions, such as dust, corrosive gases, high humidity with risk of condensation and dripping water, splashing liquid, etc.this enables the drive to be used in an enclosure where the maximum internal temperature reaches 50c.
8 product data sheet connections and schema ATV212HU22N4 recommended wiring diagram 3-phase power supply a1: atv ? 212 drive km1: contactor q1: circuit breaker q2: gv2 ? l rated at twice the nominal primary current of t1 q3: gb2cb05 s1, s2: xb4 ? b or xb5 ? a pushbuttons t1: 100 ? va transformer 220 ? v secondary (1) fault relay contacts for remote signalling of the drive status (2) connection of the common for the logic inputs depends on the positioning of the switch (source, plc, sink) (3) reference potentiometer sz1rv1202 all terminals are located at the bottom of the drive. install interference suppressors on all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. switches (factory settings) voltage/current selection for analog i/o (via and vib) voltage/current selection for analog i/o (fm) selection of logic type (1) negative logic (2) positive logic other possible wiring diagrams
9 logic inputs according to the position of the logic type switch source position sink position plc position with plc transistor outputs (1) plc (1) plc 2-wire control f: forward r: preset speed (2) atv ? 212 control terminals 3-wire control f: forward r: stop res: reverse (2) atv ? 212 control terminals ptc probe (2) atv ? 212 control terminals (3) motor analog inputs voltage analog inputs external +10 ? v (2) atv ? 212 control terminals (4) speed reference potentiometer 2.2 to 10 ? k (2) atv ? 212 control terminals
10 analog input configured for current: 0-20 ? ma, 4-20 ? ma, x-y ? ma (2) atv ? 212 control terminals (5) source 0-20 ? ma, 4-20 ? ma, x-y ? ma analog input via configured as positive logic input (source position) (2) atv ? 212 control terminals analog input via configured as negative logic input (sink position) (2) atv ? 212 control terminals
11 product data sheet performance curves ATV212HU22N4 derating curves the derating curves for the drive nominal current (in) depend on the temperature, the switching frequency and the mounting type (a, b or c). for intermediate temperatures (45c for example), interpolate between 2 curves. x switching frequency


▲Up To Search▲   

 
Price & Availability of ATV212HU22N4

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X